Clean room classification (ISO 14644-1 Cleanroom Standards)

Clean room and the classification of clean room are the most critical topic of the pharmaceutical industry. For the manufacturing of the pharmaceuticals products (Active pharmaceutical ingredients, Tablets, capsules, sterile dosage form) cleanroom room area is required .According to the types of the product manufacturer has to maintain the clean room area.

What is clean room Area?

Cleanroom is the controlled area where the specified size of the airborne particles are allowed with required pressure humidity and temperature to prevent the cross contamination and the microbial contamination.

Here, we are talking about the control environment control means prevention of dust, prevention of the entry of larger particle, (Only specified particle sized entry is possible into the clean room. The size of the particle is mentioned in the guideline). There are the different guidelines available which explains about the requirement for the clean room area in pharmaceutical industry.

Guideline for the Clean Room Classification:

There are so many guidelines which explain the cleanroom classification. Now a day the other guidelines are obsoleted.  ISO 14644 is the guideline which is the standard guideline followed for the clean room classification and qualification

ISO 14644 is a guideline which defines the cleanroom classification. According to the 14664 guideline cleanroom can be classified into following classes. As per the ISO guideline the clean rooms are classified as ISO 1 to ISO 9 class.

Generally form ISO 5 area to ISO 9 is used in pharmaceutical industry. Example: For the manufacturing of the sterile product ISO 5 area is required.

Particle size range 0.3 µ, 0.5 µ, 1.0 µ, 3.0 µ, 5.0 µ, 10.0 µ. Reading shall be taken for 0.5 V µ and 5.0 V µ particle size.

US Federal Standard   FED STD 209E guideline was used for the classification of the clean room according to the FED STD 209 clean room are classified as class 1, class 10, class 100, class 1000.class 10000 class 100000 which equivalent to the class following ISO class Comparison is mentioned in below table

Currently ED STD 209 E guide line is not used as FED released the notation of cancellation and superseded for ED STD 209 E, airborne particulate cleanliness classes in cleanroom and cleans zones in 2001.The guideline was superseded by standard written for the International organization for the standardization.

British standard BS 5295 guideline was used for the clean room classification According to the guideline clean room classified as the class1, class 2, class 3, and class 4. BS 5295 is British guideline which has been also obsoleted and withdraws from the year 2007 and replaced with ISO 14644-6:2007.

Class

maximum particles/m3

FED STD 209E
equivalent

>=0.1 µm

>=0.2 µm

>=0.3 µm

>=0.5 µm

>=1 µm

>=5 µm

ISO 1

10

2

 

 

 

 

ISO 2

100

24

10

4

 

 

 

ISO 3

1,000

237

102

35

8

 

Class 1

ISO 4

10,000

2,370

1,020

352

83

 

Class 10

ISO 5

100,000

23,700

10,200

3,520

832

29

Class 100

ISO 6

1,000,000

237,000

102,000

35,200

8,320

293

Class 1,000

ISO 7

 

 

 

352,000

83,200

2,930

Class 10,000

ISO 8

 

 

 

3,520,000

832,000

29,300

Class 100,000

ISO 9

 

 

 

35,200,000

8,320,000

293,000

Room Air


BS 5295 Cleanroom Standards

 

maximum particles/m3

Class

>=0.5 µm

>=1 µm

>=5 µm

>=10 µm

>=25 µm

Class 1

3,000

 

0

0

0

Class 2

300,000

 

2,000

30

 

Class 3

 

1,000,000

20,000

4,000

300

Class 4

 

 

20,000

40,000

4,000


Requirement of the Clean room in to the pharmaceutical industry:

Cleanroom classification is required in pharmaceutical industry to prevent the microbial contamination in to the manufacturing area.

In pharmaceutical Industry airborne particle may adversely affect the product quality hence to control the airborne particle into the manufacturing area. In Cleanroom area only specified airborne particle is allowed.

Prevent the dust particle entry into the manufacturing area.  

Prevent the microbial contamination in the product.

Related Post:

Pass Box in pharmaceutical Industry

Difference between dynamic Pass box and Static pass box  


Gel Permeation Chromatography (Type of Size exclusion Chromatography)

Gel permeation chromatography is one of the high performance liquid chromatography. It is the one type of the Size exclusion chromatography.

There is two type of Size exclusion chromatography

Gel permeation chromatography

Gel filtration chromatography

The main difference between the Gel permeation chromatography and the gel filtration chromatography is the Mobile Phase

Gel permeation Chromatography:

Where the solid stationary phase and mobile phase is non-polar.

Gel permeation Chromatography Principle

The Basic principle of the Size Exclusion Chromatography is Smaller the particle of the analyte is trapped into the Column bed. The column bed act as sieve which trapped the smaller molecule of the analyte easily, Hence Smaller the molecule of the analyte, it retains for more period time in SEC column temporarily

Large molecules are not trapped in the column bed. Large molecule passes around the bed and excluded from the column bed. Larger the molecule quickly pass through the column

Large molecules are eluted first from the column and then small molecules are eluted

In other terms, we can say that large molecule has less retention time while the small molecule has more retention time.

 


Parts of HPLC (High Performance Liquid Chromatography)

HPLC is a technique for separation, identification and quantification of components in a mixture. It is especially suitable for compounds which are not easily volatilized, thermally unstable and have high molecular weights.

The instrumentation of the HPLC system is quite complex there are so many critical parts in HPLC system. 


Following are the different parts of the HPLC system:

Solvent Reservoir

Tubing

Pumps

Injector system

Guard column

Analytical column

Detectors

Recorders & integrator

Waste collector


The liquid phase is pumped at a constant rate to the column packed with the stationary phase. Before entering the column the analysis sample is injected into the carrier stream. On reaching the column the sample components are selectively retained on the basis of physio-chemical interactions between the analyte molecules and the stationary phase. The mobile phase moving at a steady rate elutes the components based on the operating conditions. Detection techniques are employed for detection and quantification of the eluted components.


Details about the part of the HPLC system:

 

These are inert containers for mobile phase storage and transport. Generally transparent glass bottles are used so as to facilitate visual inspection of mobile phase level inside the container. Stainless steel particulate filters are provided inside for removal of particulate impurities in the mobile phase if any.

 Mobile phase serves to transport the sample to the system. Essential criteria of mobile phase are inertness to the sample components. Pure solvents or buffer combinations are commonly used. The mobile phase should be free of particulate impurities and degassed before use.

Following are the characteristic of the mobile phase:

-It should be inert to mobile phase.

-Made up of stainless steel or glass .

-Capacity:500ml or more than that.

-Degasing: to prevent formation of gas bubble in the detector .it is done by various methods: By distillation system, by vacuum pumping system, by heat solvent with stirring,


Tubing:

The nature of the tubing used to connect all parts of the system deserves some attention.

The inside diameter of the tubing prior to the injection device is not critical but the tubing should be inert have the ability to withstand pressure & be able to carry sufficient volume.


Pumps:

Variations in flow rates of the mobile phase effect elution time of sample components and result in errors. Pumps provide constant flow of mobile phase to the column under constant pressure

Ideal  requirement:

Produce very high pressure 5000-10000 psi.

Produce pulse free output.

Flow control and flow reproducible.

Flow rate of m.p. should be in the range of 0.1-10 ml/min.

All material of construction should be corrosion free like s.s., Teflon.

2 types of pumps available

    1. Constant flow rate.

     2. Constant pressure.

Injector System:

Injectors are used to provide constant volume injection of sample into the mobile phase stream. Inertness and reproducibility of injection are necessary to maintain high level of accuracy.

Ideal requirement:

Sample should be injected in a narrow plug.

Size of sample should be variable.

Should be reproducible.

System must

2 types of the injector system are there

Septum Injector and loop Injector 


Guard Column:

 Guard column has very small quantity of adsorbent and improves the life of the analytical Column. They do not have any contribution in the separation.

  It also acts as a pre filter to remove particulate matter, if any, and other material.

  Guard column has the same material as that of the analytical columns.


Analytical Columns:

A column is a stainless steel tube packed with stationary phase. It is a vital component and should be maintained properly as per supplier instructions for getting reproducibility separation efficiency run after run.

Analytical column is that important part of HPLC technique which decides the efficiency of separation.

 There are several stationary phases available depending upon the technique or mode of separation used.

Column material:

The columns are made up of either Stainless steel, glass, polyethylene and PEEK( poly ether ,ether ketone).

  Column length:  Varies from 5cm to 30cm

  Column diameter: Ranges from 2mm to 50mm

  Particle size      :  From 1μ to 20μ 

  Particle nature:  Spherical, uniform sized, porous materials are used.

Column Oven

Variation of temperature during the analytical run can result in changes of retention time of the separated eluting components. A column oven maintains constant column temperature using air circulation. This ensures a constant flow rate of the mobile phase through the column.

 

Detector

A detector gives specific response for the components separated by the column and also provides the required sensitivity. It has to be independent of any changes in mobile phase composition. Majority of the applications require UV-VIS detection though detectors based on other detection technique are also popular these days.

Ideal requirement:

High sensitivity.

Reproducible response &give response to all analyte.

Response should be linear over wide range of concentration.

Should not be sensitize to flow rate fluctuation or temp. Change or change in composition.

Capable of withstand at high pressure.


Data Acquisition & Control

Modern HPLC systems are computer based and software controls operational parameters such as mobile phase composition, temperature, flow rate, injection volume and sequence and also acquisition and treatment of output.

These are the main parts of a basic HPLC system more specialized equipment might also have solvent selection valves, vacuum degasser, auto samplers, column switchers, pre or post column derivatization and fraction collectors.

 


Difference between Ascending and Descending Chromatography

Descending chromatography and the ascending chromatography are the types of the planar chromatography. It depends on the direction of the mobile phase.

The main difference between the descending chromatography and ascending chromatography is the following:

When the mobile phase moves in the upward direction it is known as the Ascending chromatography. While descending chromatography move in downward the direction it is known as the Descending chromatography.

Ascending chromatography

Descending chromatography

The mobile phase moves in an upward direction.

The mobile phase moves to a downward direction.

The mobile phase move up by the capillary action

The mobile phase  move down by the gravitational force.

The solvent reservoir is at the top of the setup.

The solvent reservoir is the bottom of the setup.

Ascending chromatography has is a simple setup.

Descending chromatography has a complex setup.

 

Related Post:

Ascending Chromatography

Descending Chromatography

Chromatography Basic

Stationary phase in Chromatography

Mobile phase in Chromatography